<div dir="ltr"><div>Hello.</div><div><br></div><div>He is sure that the keys are well?</div><div><br></div><div>try to translate the MIB DISMAN-EVENT-MIB :: sysUpTimeInstance</div><div><br></div><div>For example:</div><div><br></div><div><span style="font-family:Calibri,sans-serif;font-size:14.6667px">/usr/lib64/nagios/plugins/</span><span style="font-family:Calibri,sans-serif;font-size:14.6667px">check_snmp </span><span style="font-family:Calibri,sans-serif;font-size:14.6667px">-H 192.168.254.2 </span><span style="font-family:Calibri,sans-serif;font-size:14.6667px">-o </span><span style="color:rgb(0,0,0)">.1.3.6.1.2.1.1.3.0 </span><span style="font-family:Calibri,sans-serif;font-size:14.6667px">-P 3 </span><span style="font-family:Calibri,sans-serif;font-size:14.6667px">-L authPriv -a MD5</span><span style="font-family:Calibri,sans-serif;font-size:14.6667px"> </span><span style="font-family:Calibri,sans-serif;font-size:14.6667px">-x DES -X v3p4ssword#2 </span><span style="font-family:Calibri,sans-serif;font-size:14.6667px">-U snmpv3user  -A v3p4ssword#1  </span></div><div><span style="font-family:Calibri,sans-serif;font-size:14.6667px"><br></span></div><div><span style="font-family:Calibri,sans-serif;font-size:14.6667px"><br></span></div><div class="gmail_extra"><br clear="all"><div><div class="gmail_signature"><div dir="ltr"><div><div dir="ltr"><div><div dir="ltr"><div><div dir="ltr"><div dir="ltr"><div dir="ltr"><div dir="ltr"><div dir="ltr"><div dir="ltr"><div dir="ltr"><div dir="ltr"><div style="font-size:12.8px">Atte.</div><div style="font-size:12.8px"><br></div><div style="font-size:12.8px"><address style="font-size:12.8px">Pablo A. Muñoz Rojas</address><address style="font-size:12.8px"><span style="font-size:small">Reseller</span><span style="font-size:small"> </span>Nagios & <a href="http://www.nagios.org/communitynetwork" target="_blank">Nagios Community Manager</a></address><address style="font-size:12.8px">P: +56-32-3140734 | C: +56-9-85499668</address><address style="font-size:12.8px">w: <a href="http://www.e-visus.cl/" target="_blank">www.e-visus.cl</a> – <a href="http://www.nagios-cl.org/" target="_blank">www.nagios-cl.org</a> | <span style="font-size:12.8px">d: Ecuador 85, Viña del Mar, Chile</span></address><address style="font-size:12.8px"><span lang="EN-US"><a href="http://www.nagios.com/verify/" target="_blank">Nagios Certified Administrator and Professional - 3HCL9F</a></span></address><address style="font-size:12.8px"><b>Nuestras redes:</b> <a href="https://cl.linkedin.com/in/pablomunozrojas/" target="_blank">Linkedin </a>- <a href="https://twitter.com/Nagios_Chile" target="_blank">Twitter </a>- <a href="http://www.e-visus.cl/?p=241" target="_blank">Line </a>- <a href="http://www.e-visus.cl/?p=241" target="_blank">skype</a> - <a href="https://www.facebook.com/evisus4nagios" target="_blank">facebook</a></address></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div>
<br><div class="gmail_quote">2015-07-07 11:17 GMT-03:00 José Pedro Brito Röseler <span dir="ltr"><<a href="mailto:pedro.roeseler@av.it.pt" target="_blank">pedro.roeseler@av.it.pt</a>></span>:<br><blockquote class="gmail_quote" style="margin:0 0 0 .8ex;border-left:1px #ccc solid;padding-left:1ex">
<div lang="PT" link="blue" vlink="purple"><div><p class="MsoNormal"><span lang="EN-US" style="color:#1f497d">Hello.<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="color:#1f497d"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="color:#1f497d">I’m trying to check the uptime of a Cisco 2960X switch on Nagios with </span><b><span lang="EN-US" style="color:#1f497d">check_</span></b><b><span lang="EN-US" style="color:#1f497d">snmp</span></b><span lang="EN-US" style="color:#1f497d"> plugin</span><span lang="EN-US" style="color:#1f497d"> but I always get the following error:<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US">[root@nagios]# /usr/lib64/nagios/plugins/check_snmp -P 3 -U snmpv3user -L authPriv -a MD5 -A v3p4ssword#1 -x DES -X v3p4ssword#2 -H 192.168.254.2 -o DISMAN-EVENT-MIB::sysUpTimeInstance<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="color:red">External command error: snmpget: Authentication failure (incorrect password, community or key)<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="color:red"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="color:#1f497d">I get the same error on the web console:<u></u><u></u></span></p><p class="MsoNormal"><span><img width="1175" height="58" src="cid:image002.png@01D0B8C5.7A582710"></span><span lang="EN-US" style="color:red"><u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="color:#1f497d">My <b>switches.conf</b> is like this:<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"># HOST DEFINITIONS<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">#<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">###############################################################################<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">###############################################################################<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"># Define the switch that we'll be monitoring<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">define host{<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">        use                     generic-switch,host-pnp<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">        host_name               cisco_2960x_IT2_Datacenter<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">        </span><span style="font-size:10.0pt">alias                   cisco 2960x 24p IT2 Datacenter<u></u><u></u></span></p><p class="MsoNormal"><span style="font-size:10.0pt">        </span><span lang="EN-US" style="font-size:10.0pt">address                 192.168.254.2<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">        hostgroups              switches_v3<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">        notification_interval   60<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">        icon_image              switch.png<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">        statusmap_image         switch40.png<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">        }<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">###############################################################################<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">###############################################################################<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">#<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"># HOST GROUP DEFINITIONS<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">#<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">###############################################################################<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">###############################################################################<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"># Create a new hostgroup for switches<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">define hostgroup{<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">        hostgroup_name  switches                ; The name of the hostgroup<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">        alias           Network Switches        ; Long name of the group<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">        }<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">define hostgroup{<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">        hostgroup_name  switches_v3             ; The name of the hostgroup<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">        alias           Network Switches with SNMP v3        ; Long name of the group<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">        }<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">###############################################################################<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">###############################################################################<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">#<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"># SERVICE DEFINITIONS<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">#<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">###############################################################################<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">###############################################################################<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">########## Switches with SNMP V3 ###################<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"># Service definition to monitor switch uptime using check_snmp<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"># Monitor uptime via SNMP<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">define service{<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">use                     generic-service<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">hostgroup_name          switches_v3<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">service_description     Uptime<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">check_command           check_snmp!-P 3 -U snmpv3user -L authPriv -a MD5 -A v3p4ssword#1 -x DES -X v3p4ssword#2 -o DISMAN-EVENT-MIB::sysUpTimeInstance<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt">}<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="font-size:10.0pt"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="color:#1f497d">If I do the same test with <b>snmpget</b>, everything runs fine:<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US">[root@nagios]# snmpget -v3 -l authPriv -u snmpv3user -a MD5 -A v3password#1 -x DES -X v3password#2 192.168.254.2 DISMAN-EVENT-MIB::sysUpTimeInstance<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="color:#00b050">DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (783093831) 90 days, 15:15:38.31<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="color:#1f497d">snmpwalk also runs without problems:<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US">[root@nagios]# snmpwalk -v3 -l authPriv -u snmpv3user -a MD5 -A v3password#1 -x DES -X v3password#2 192.168.254.8 DISMAN-EVENT-MIB::sysUpTimeInstance<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="color:#00b050">DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (783167495) 90 days, 15:27:54.95<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="color:#1f497d">Do you have any idea of what might be happening? I’m using a FAN installation on Centos.<u></u><u></u></span></p><p class="MsoNormal">[root@nagios]# uname -a<span lang="EN-US" style="color:#1f497d"><u></u><u></u></span></p><p class="MsoNormal">Linux nagios 2.6.18-400.1.1.el5 #1 SMP Thu Dec 18 00:59:53 EST 2014 x86_64 x86_64 x86_64 GNU/Linux<u></u><u></u></p><p class="MsoNormal"><span style="color:#1f497d"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="color:#1f497d">Thanks in advance for your help!<u></u><u></u></span></p><p class="MsoNormal"><span lang="EN-US"><u></u> <u></u></span></p><p class="MsoNormal"><span lang="EN-US" style="color:#1f497d">Best regards,<u></u><u></u></span></p><p class="MsoNormal"><span style="color:#595959">Pedro Röseler<u></u><u></u></span></p></div></div></blockquote></div><br></div></div>